Page 1: ... underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective ...

Page 2: ...413Bs as HP E1413 Option 19 Enclosed is the User s Manual for the HP E1509 Signal Conditioning Plug on Insert this manual in your HP E1413 E1313 manual behind the Signal Conditioning Plug ons divider Manual Part Number E1509 90001 Printed JANUARY 1996 Edition 1 Printed in U S A E 0196 E1509 90001 E1509 90001 Copyright Hewlett Packard Company 1993 1994 1996 ...

Page 3: ......

Page 4: ...gister Based commands and explains the capabilities of this SCP Finally it covers specifications for this SCP The contents of this manual are Installation 3 Identifying the Plug on 3 Connecting To The Terminal Module 4 Programming With SCPI Commands 6 Programming With Register Commands 8 Specifications 10 Installation Installation for this Plug on is common to several others and is covered in Chap...

Page 5: ...opriate stickers are as follows For HP E1413C and above Terminal Modules use stickers for HP E1509 SCPs The connections are shown in Figure 1 For HP E1313 Terminal Moduless use stickers for HP E1509 SCPs The connections are shown in Figures 2 and 3 For HP E1413B and below Terminal Modules use stickers for HP E1413 Option 19 SCPs The connections are shown in Figure 4 Figure 1 HP E1509 C Size Termin...

Page 6: ...Terminal Module Connections Ch 00 31 Figure 3 HP E1509 B size Terminal Module Connections Ch 32 63 Figure 4 HP E1413 Option 19 Terminal Module Connections Connecting To The Terminal Module HP E1509 Fixed Filter Amplifier SCP 5 ...

Page 7: ...CTYP 100 query SCP type ch 0 enter statement here Querying the Filter Cutoff Frequency While the the HP E1509 does not provide programmable cutoff frequency the filter frequency can be queried The response to this query will always be 7 To query any channel for its cutoff frequency use the INPut FILTer LPASs FREQuency channel command The INP FILT FREQ command returns the numeric cutoff value curre...

Page 8: ...l 8 enter statement here Detecting Open Transducers This SCP provides a method to detect open transducers When Open Transducer Detect OTD is enabled the SCP injects a small current into the HIGH and LOW input of each channel The polarity of the current pulls the HIGH inputs toward 17 volts and the LOW inputs towards 17 volts If a transducer is open measuring that channel will return an over voltag...

Page 9: ...ained on the SCP The first channel on each SCP is 0 8 16 24 32 40 48 and 56 To enable Open Transducer Detection on all channels on SCPs 1 and 3 DIAG OTD ON 100 116 0 is on SCP 1 and 16 is on SCP3 To disable Open Transducer Detection on all channels on SCPs 1 and 3 DIAG OTD OFF 100 116 Register Based Programming The register based commands shown here are covered in Appendix D of the HP E1413 E1313 ...

Page 10: ...e will be returned to the Query Response Register Detecting Open Transducers Open Transducer Detection OTD is controlled by bits in the Card Control Register For more information on OTD see Figure 1 Card Control Register Base 1216 15 14 14 13 12 11 10 8 7 0 PSI Pwr Reset FIFO Mode unused FIFO Clear VPPEN A24 Window Open Transducer Detect Writing a one 1 to a bit enables open transducer detect on t...

Page 11: ...850 C Resistance Opt 15 required 128 ohms to 131 Kohms FS Strain 25 000 µe or limit of linear range of strain gage Maximum input voltage Normal mode plus common mode Operating 16 V peak Damage level 42 V peak Maximum common mode voltage Operating 16 V peak Damage level 42 V peak Normal mode rejection 7Hz 3dB 60Hz 25dB Common mode rejection 0 60Hz 100dB Input impedance 100 Mohm 10 each differential...

Page 12: ...perature accuracy specifications include instrument and firmware linearization errors The linearization algorithm used is based on the IPTS 68 78 standard transducer curves Add your transducer accuracy to determine total measurement error Type E A D Filter 200 to 0 C 0 to 200 C 200 to 400 C 400 to 800 C OFF ON 1 25 C 1 20 C 0 10 C 0 095 C 0 12 C 0 10 C 0 125 C 0 11 C Type EEXtended A D Filter 200 ...

Page 13: ... 65 C 65 to 85 C OFF ON 0 0061 C 0 0055 C 0 011 C 0 010 C 100Ω Reference RTD A D Filter 125 to 70 C OFF ON 0 080 C 0 080 C 100Ω RTD A D Filter 200 to 75 C 75 to 300 C 300 to 600 C 600 to 970 C OFF ON 0 08 C 0 07 C 0 21 C 0 18 C 0 27 C 0 25 C 0 37 C 0 35 C 2252Ω Thermistor A D Filter 63 to 70 C 70 to 83 C 83 to 100 C OFF ON 0 008 C 0 007 C 0 009 C 0 008 C 0 014 C 0 012 C 5KΩ Thermistor A D Filter 1...

Page 14: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...