8.
Frequency
Tracking
Range
8.
W
ait
for
the
counter
to
gate
two
or
three
times
,
then
record
the
counter
reading
below
as
the
maximum
frequency
.
Maximum
frequency
MHz
9.
On
the
tracking
generator
,
set
the
TRA
CKING
ADJUST
control
fully
counterclockwise
.
10.
W
ait
for
the
counter
to
gate
two
or
three
times
,
then
record
the
counter
reading
below
as
the
minimum
frequency
.
Minimum
frequency
MHz
11.
Subtract
the
minimum
frequency
from
the
peaked
frequency
and
record
the
result
as
the
negative
frequency
variation.
The
variation
should
be
greater
than
5
kHz.
P
erform
the
tracking
oscillator
range
adjustment
if
the
variation
is
less
than
5
kHz.
Negative
frequency
variation
kHz
12.
Subtract
the
maximum
frequency
from
the
peaked
frequency
and
record
the
result
as
the
positive
frequency
variation.
The
variation
should
be
greater
than
5
kHz.
P
erform
the
tracking
oscillator
range
adjustment
if
the
variation
is
less
than
5
kHz.
P
ositive
frequency
variation
kHz
4-34
P
erformance
T
ests
HP
85640A
RF
T
racking
Generator
Operation
and
Service
Manual