2.
Maximum
Leveled
Output
P
ower
2.
Maximum
Leveled
Output
P
ower
Specication
Maximum
leveled
output
power:
0
dBm
Related
A
djustment
Tracking
generator
power
level
adjustments
Description
The
tracking
generator's
RF
OUTPUT
is
connected
to
the
host
spectrum
analyzer's
INPUT
50.
Tracking
is
adjusted
at
300
MHz
for
a
maximum
signal
level.
The
tracking
generator's
RF
OUTPUT
is
then
terminated
in
50.
The
tracking
generator
is
set
to
specied
output
level
settings
and
slowly
swept
from
300
kHz
to
2.9
GHz.
The
UNLEVELED
indicator
is
monitored
to
check
for
an
unleveled
condition.
If
the
UNLEVELED
indicator
is
not
activated
during
the
sweep
,
the
tracking
generator
meets
this
specication.
If
the
UNLEVELED
indicator
is
activated
during
the
sweep
,
the
OUTPUT
LEVEL
vernier
setting
is
decreased
until
the
output
remains
leveled
during
the
entire
sweep
.
This
setting
is
recorded.
Figure
4-3.
Maximum
Leveled
Output
P
ower
T
est
Setup
Equipment
Host
spectrum
analyzer
.
.
.
.
.
.
HP
8560A/E,
8561A/B/E,
HP
8562A/B
,
or
HP
8563A/E
50
termination
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HP
908A
Cables
Type
N,
62
cm
(24
in)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HP
11500B/C
BNC,
62
cm
(24
in)
(3
required)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
8120-1839
SMA,
52
cm
(20
in)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5061-9038
HP
85640A
RF
T
racking
Generator
Operation
and
Service
Manual
P
erformance
T
ests
4-9