Figure
4-18.
RE02
T
est
Setup
The
RE02
requiremen
ts
are
applicable
to
radiated
emissions
from
equipmen
t
and
subsystems,
cables,
and
in
terconnecting
wiring.
Emissions
from
an
tennas
are
not
included.
As
with
other
tests,
the
in
ten
t
of
the
pro cedure
is
to
simulate
the
actual
installation
conditions
of
the
equipmen
t.
RE02
limits
and
pro cedures
are:
Narrowband
test:
14
kHz
to
10
GHz.
Broadband
test:
14
kHz
to
1
GHz.
Do
es
not
apply
to
radiation
from
an
tennas.
V
ertical
and
horizontal
p olarization
m
ust
b e
tested
ab o
v
e
30
MHz.
Prob e
with
a
lo
op
to
nd
the
p oint
of
maxim
um
emission
and
orient
this
p oint
one
meter
from
an
tenna.
F
or
large
equipmen
t
or
systems,
the
an
tenna
should
b e
mov
ed
to
test
a
one-meter
distance
from
v
arious
p oints.
T
ypical
an
tennas:
14
kHz
to
30
MHz
(active
ro
d)
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
HP
11966B
30
to
300
MHz
(biconical)
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
HP
11966C
200
MHz
to
2
GHz
(double-ridged
horn)
:
:
:
:
:
:
:
:
:
:
:
:
:
HP
11966I
1
to
18
GHz
(double-ridged
horn)
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
HP
11966E
HP
8572A
EMI
Receiv
er
User's
Guide
Making
Typical
Measurements
4-27