Chapter 3
81
A-Class System Service
A-Class Server Trouble Shooting
Chassis Code Summary
Operating Status (OSTAT) and chassis codes are generated by A-Class server
firmware. OSTAT and chassis codes can be read from stored locations or viewed
'real time' via the HSC Remote Management card.
Chassis codes displayed during selftest only appear at the console. They will appear
on either the ASCII console or the Web console. Below is an example of how
chassis codes appear in response to a 'control b' key sequence:
WARNING: The processor has failed selftest.
A processor selftest failure requires replacing the
EBU.
WARNING: One or more memory banks were not
configured due to a SIMM size mismatch or a SIMM
failure. For more details, use the MEMORY
command in the INFORMATION menu.
Use the MEMORY command in the
INFORMATION menu to determine correct
configuration.
WARNING: The Bus Converter has failed.
A Bus Converter failure requires replacing the
EBU.
WARNING: FAN FAILURE HAS BEEN
DETECTED. THE SYSTEM WILL BE
POWERING DOWN. PLEASE CALL YOUR
SERVICE REPRESENTATIVE
A chassis fan failure requires replacing the EBU.
ERROR: A3342A AP Card must be in bottom slot
only.
Move the AP A3342A card to the bottom slot.
ERROR: HSC card in wrong slot. Move to bottom
slot.
A mix of HSC and PCI cards has been detected.
The HSC card must be installed in the bottom
slot.
Firmware Warning Messages
Description/Action Required
Summary of Contents for 9000 A-180
Page 1: ...User s Manual HP 9000 Model A 180 Manufacturing Part Number Aclassdoc00 February 2000 ...
Page 17: ...Chapter 2 17 A Class Server Installation 2 A Class Server Installation aclassdoc00 ...
Page 66: ...66 Chapter2 A Class Server Installation A Class Server System Software Configuration ...
Page 67: ...Chapter 3 67 A Class System Service 3 A Class System Service aclassdoc00 ...
Page 122: ...122 Chapter3 A Class System Service Replacing an A Class Server Exchange Base Unit EBU ...