2-27
R Class System Memory Upgrade
Troubleshooting Memory Configuration Error Symptoms
Downloading the Firmware Patch using FTP.
1. Connect to HPESC via ftp. You must initiate downloading from an open subnet
system as:
>ftp us-support.external.hp.com
(If you do not have an open subnet system, try using rftp instead of ftp.)
2. Login as “anonymous”.
3. At the Password prompt, enter your e-mail address as the password.
4. Change to the directory containing the firmware patches:
> cd firmware_patches/hp/cpu
If desired, review the contents of the directory by using the
ls
command. For
each patch, there is an accompanying text file (patchfilename.txt). The text file
contains the patch description and the instructions for creating the patch tape.
5. Download the appropriate patch file and text file:
get <patchfilename>
get <patchfilename>.txt
6. Follow the instructions in the Readme file to create a bootable tape and to update
PDC.
Summary of Contents for 9000 Model D280
Page 4: ...iv Contents ...
Page 14: ...1 8 D Class System Memory Upgrade Memory Installation Procedure ...
Page 25: ...1 19 D Class System Memory Upgrade Memory Installation Procedure ...
Page 55: ...2 15 R Class System Memory Upgrade Memory Installation Procedure ...
Page 68: ...2 28 R Class System Memory Upgrade Troubleshooting Memory Configuration Error Symptoms ...