Chapter 6
Troubleshooting and Installation-Related Tasks
Superdome 64 Way Fails to Boot
116
Superdome 64 Way Fails to Boot
Among the reasons the Superdome 64 Way may not boot is that the firmware versions in the two cabinets are
not identical.
To verify that the firmware for the cabinets is identical:
Step 1. From the Guardian Service Processor (GSP) Main Menu, enter
cm
.
Step 2. At the GSP Command Menu, enter
de
.
Step 3. Select the
s
option.
Step 4. Enter the cabinet number.
Be sure to keep track of the cabinet number you choose. Later you will choose the cabinet number
of the other cabinet in order to compare the firmware revision numbers.
The following screen appears:
Figure 6-2GSP de Command with s Option
Step 5. Note the PDC firmware revision number next to the PDC FW Revision field.
Step 6. Check the firmware revision number for the firmware in the other cabinet.
Step 7. Compare the numbers.
If the numbers are different, the firmware for one or both of the cabinets may have to be updated,
depending on the revision number of the most current firmware.
Summary of Contents for 9000 Superdome
Page 8: ...Contents 8 ...
Page 9: ...9 Preface ...
Page 21: ...21 IEC 60417 IEC 335 1 ISO 3864 IEC 617 2 International Symbols ...
Page 22: ...22 Figure 9 Superdome Declaration of Conformity Page 1 ...
Page 23: ...23 Figure 10 Superdome Declaration of Conformity Page 2 ...
Page 24: ...24 ...
Page 32: ...Chapter 1 Introduction Installation Warranty 8 ...
Page 130: ...Chapter 4 Verifying and Booting Superdome Enabling iCOD 106 ...
Page 172: ...Appendix A hp Server rx2600 Support Management Station Configuring the SMS 148 ...
Page 184: ...Appendix C Superdome LAN Interconnect Diagram 160 ...
Page 193: ...Appendix F 169 F A180 Support Management Station ...
Page 230: ...Appendix G Connecting Multiple SPU Cabinets Connecting Cables 206 ...
Page 256: ...Appendix H JUST Exploration Tool Error Conditions 232 ...