Chapter 3
Preparing Superdome for Booting
Connecting the CE Tool to the A500 Support Management Station
67
Connecting the CE Tool to the A500 Support Management Station
NOTE
The information in the following sections applies to the A500 Support Management Station
(SMS) only.
Connecting the CE Tool to the SMS allows you to configure the SMS. It requires a 9-pin female to 25-pin male
serial cable:
Step 1. Disconnect the serial cable from the Local RS-232 port on the GSP and the CE tool.
Step 2. Connect one end of the serial cable (9-pin female to 25-pin male, P/N 24542G) to the serial port on
the CE tool.
In Figure 3-29, this connection is shown as a dotted line between the CE TOOL (PC) and the SMS.
Figure 3-29Superdome LAN Interconnect Diagram
Step 3. Connect the other end of the serial cable to the port on the SMS labeled Console UPS Port.
PC/Workstation
Console Access
NOTE:
Preferred method
of GSP access
CE Tool (PC)
For initial install of SMS,
serial cable 24542G needed.
Customer Site LAN
(if desired)
Modem
Private LAN Port
Customer LAN Port
RS232 Local
RS232 Remote
Guardian Service
Processor (GSP)
*LAN Hub
0000
LAN Console
Port
10/100 Base-T Port
Support Management
Station
High Availability Observatory
or other info structure to
remotely connect to the
HP Service Location or
customer site LAN.
Summary of Contents for 9000 Superdome
Page 8: ...Contents 8 ...
Page 9: ...9 Preface ...
Page 21: ...21 IEC 60417 IEC 335 1 ISO 3864 IEC 617 2 International Symbols ...
Page 22: ...22 Figure 9 Superdome Declaration of Conformity Page 1 ...
Page 23: ...23 Figure 10 Superdome Declaration of Conformity Page 2 ...
Page 24: ...24 ...
Page 32: ...Chapter 1 Introduction Installation Warranty 8 ...
Page 130: ...Chapter 4 Verifying and Booting Superdome Enabling iCOD 106 ...
Page 172: ...Appendix A hp Server rx2600 Support Management Station Configuring the SMS 148 ...
Page 184: ...Appendix C Superdome LAN Interconnect Diagram 160 ...
Page 193: ...Appendix F 169 F A180 Support Management Station ...
Page 230: ...Appendix G Connecting Multiple SPU Cabinets Connecting Cables 206 ...
Page 256: ...Appendix H JUST Exploration Tool Error Conditions 232 ...