12
Step1
Align the screw holes on the mounting brackets with the screw holes on the firewall chassis, and then use
a Phillips screwdriver to fasten the screws, as shown in callout 1 in
.
Step2
Attach the load-bearing screws to the appropriate screw holes on the firewall chassis, and use a Philips
screwdriver to fasten the screws, as shown in callout 2 in
.
Figure 8
Install the front mounting brackets and load-bearing screws to the firewall
Installing the firewall to the rack
Follow these steps to install the firewall to the rack:
Step1
Supporting the firewall bottom with one hand, push the firewall into the rack horizontally, and make sure
that the upper edges of the rear mounting brackets make close contact with the load-bearing screws on
the firewall.
Step2
Fix the firewall horizontally by fastening the front mounting brackets at both sides to the rack with
appropriate pan head screws. The specifications of pan head screws must satisfy the installation
requirements, and rustproof treatment has been made to their surfaces.
Figure 9
Fix the firewall to the rack
(1) load-bearing screws