55
To do…
Use the command…
Remarks
Configure the
type of terminal
display
terminal type
{
ansi |
vt100
}
Optional
By default, the terminal display type is ANSI.
The device supports two types of terminal
display: ANSI and VT100. HP recommends you
to set the display type of both the device and the
client to VT100. If the device and the client use
different display types (for example, hyper
terminal or Telnet terminal) or both are set to
ANSI, when the total number of characters of the
currently edited command line exceeds 80, an
anomaly such as cursor corruption or abnormal
display of the terminal display may occur on the
client.
Configure the
user privilege
level for login
users
user privilege level
level
Optional
3 by default.
Set the
maximum
number of lines
on the next
screen
screen-length
screen-length
Optional
By default, the next screen displays 24 lines at
most.
A value of 0 disables the function.
Set the size of
the history
command
buffer
history-command
max-size
value
Optional
By default, the buffer saves 10 history commands
at most.
Set the
idle-timeout
timer
idle-timeout
minutes
[
seconds
]
Optional
The default idle-timeout is 10 minutes. The system
automatically terminates the user’s connection if
there is no information interaction between the
device and the user within the idle-timeout time.
Setting idle-timeout to 0 disables the timer.
Set the
maximum
interval allowed
between
off-hook and
dialing
modem timer answer
time
Optional
By default, the interval is 60 seconds.
Configure a
modem to
operate in
auto-answer
mode
modem auto-answer
Optional
By default, a modem operates in non-auto
answer mode.
Enable modem
call-in/call-out
on the user
interface
modem
{
both
|
call-in
|
call-out
}
Optional
By default, both modem call-in and call-out are
disabled.