77
Network diagram
Figure 51
Network diagram for monitoring and managing the firewall module
Configuration procedure
The following configuration uses a switch as an example. The configuration on a router is the same.
1.
Log in to the firewall module from the network device
# Configure the AUX user interface of the firewall module.
<FIREWALL card> system-view
[FIREWALL card] user-interface aux 0
[FIREWALL card-ui-aux0] authentication-mode none
[FIREWALL card-ui-aux0] user privilege level 3
[FIREWALL card-ui-aux0]
# Log in to the firewall module.
<Switch> oap connect slot 3
Connected to OAP!
<FIREWALL card>
2.
Configure the clock synchronization timer and the monitoring timer
•
Configuration on the network device
# Enable ACSEI server.
<Switch> system-view
[Switch] acsei server enable
# Enter ACSEI server view
[Switch] acsei server
# Set the clock synchronization timer to 10 minutes
[Switch-acsei server] acsei timer clock-sync 10
# Set the monitoring timer to 10 seconds
[Switch-acsei server] acsei timer monitor 10
# Enable ACSEI client on the Ten-GigabitEthernet 0/0 interface.
<FIREWALL card> system-view
[FIREWALL card] interface Ten-GigabitEthernet0/0
[FIREWALL card] acsei-client enable
Configuration verification
1.
Restart the firewall module on the network device.
<Switch> oap reboot slot 3
This command will recover the OAP from shutdown or other failed state.