75
XFP port LEDs
The LPUs provide two LEDs (LINK and ACT) for each XFP port to indicate the link status and data
receiving/forwarding status of the XFP ports.
Table 45 XFP port LED description
LINK ACT Description
On
Flashing
A link is present, and the XFP interface is receiving or sending data.
On
Off
A link is present, but no data is being received or sent.
Off
Off
No link is present.
Switching fabric module LEDs
The switching fabric module has one RUN LED and one ALM LED to indicate its operating status.
Table 46 Switching fabric module LED description
RUN LED
ALM LED
Description
Flashing (0.5 Hz)
Off
The switching fabric module is working properly.
Off
On
The switching fabric module is faulty.
Flashing (0.5 Hz)
On
The temperature of the switching fabric module has exceeded the
upper or lower limit.
Off
Off
The switching fabric module has not started.
On
Off
The switching fabric module is up.
Fan tray status LEDs
The fan trays for the A10500 switches have one OK LED and one FAIL LED to indicate its operating status.
Table 47 Fan tray LED description
OK FAIL Description
On
Off
The fan tray is working properly.
Off
On
The fan tray is faulty.
Off
Off
The fan tray is not powered on.
Power supply LEDs
The 2500W AC Power Supply has one AC LED and one DC LED to indicate its operating status.