background image

Upgrade Overview

For this upgrade, you are adding additional library modules to increase the library's capacity by twenty slots.

Though the procedures are described and illustrated in the

, here is an

overview of the entire upgrade procedure:

Remove the following front panel components on the existing library to protect them during the

upgrade:

Cosmetic enclosure for standalone libraries

Top cover

Forehead

Chin-plate

Display cover

Display

Black sheet-metal RFI shield between the display and chassis

Remove the silver label from the top of the existing library to allow the interconnect cable to be

connected between the motherboards on both modules.
For 20 to 40-slot upgrades, add the vertical lift assembly to the transport assembly. The vertical lift

assembly and lift circuit board are included with the upgrade kit and enable the transport to have vertical

motion.
Install the upgrade module on top of the existing library. Ensure the modules are aligned side-to-side

and locked into place.
Secure the two modules together with screws.
For 20 to 40-slot upgrades, re-install the vertical lift/transport assembly into the top of the chassis.
Install the interconnect cable between the motherboards on both modules. Be careful that you align the

cable correctly so that you do not bend the connector pins.
Add one upgrade label to the pull-out tabs at the back of the library. Add the second upgrade label

underneath the front left magazine on the lowest library module. These labels enabls warranty tracking.
Move the display to the top module to maintain consistency with the factory configuration and optimize

user viewing. You will need to exchange the black sheet-metal RFI shields between the existing library

module and the upgrade module to allow you to move the display to the top level.
Replace the following front panel components:

Display cover

Viewing window

Chin-plates

Cosmetic doors

Connect the power cord and power on the library.
Verify the connection and run diagnostic tests.

Modular Scalability Upgrade Guide

1

1
1

1
1

1

1
1
1

1

1

1

!

!

!

!

!

!

!

!

!

!

!

Installation Overview

Upgrade Kit Contents

Overview of

Library Components

TOOLS REQUIRED:

Phillips Screw Driver

Torque Driver -T8, T10 , T15, T25

Forehead

Chin Plate

Hardware

Bag

Power Cord

Interconnect

Cable

Clipnut

Template

Upgrade

Labels

Right

Cosmetic

Door

Viewing

Window

Left

Cosmetic

Door

Vertical Lift

Circuit Board

Vertical Lift

Assy

Library

Chassis

Plastic Slider

Tools

Safety Stop

Bar

(

Depending on your upgrade

configuration,  not all parts

are included)

Reviews: