Zoning Concepts and Guidelines
66
Zoning Version 3.1.x/4.1.x User Guide
Fabrics Composed of StorageWorks 2 Gb SAN Switch and
StorageWorks Core Switch Models
StorageWorks 2 Gb SAN switches and StorageWorks Core switches enable
hardware enforced zoning on Domain/Port zones and WWN zones. Mixed zones
will not be hardware enforced. Overlap of like zone types will not result in the loss
of hardware enforcement. Overlap with another zone type will result in the loss of
hardware enforcement. As in the StorageWorks 1 Gb SAN switches, connecting a
device specified by WWN into a port specified in a Domain/Port zone will result
in loss of the hardware enforcement in both zones.
Fabrics Composed of 1 Gb SAN, 2 Gb SAN, and Core Switch Models
In mixed fabrics, each switch type continues to enable hardware enforcement of
zoning according to the conditions established above. The challenge is that the
administrator must now know which switch type the device is attached to, in order
to determine if hardware enforcement will be active. This is accomplished using
the command
zoneShow
.
Best Practices for Hardware Zone Enforcement
When a site policy has been established requiring hardware enforcement, it
certainly is desired that the hardware enforcement always occur. From the
preceding paragraphs, it should be clear that there are cases when determining the
applicability of hardware enforcement can be difficult. Three basic cases have
simple rules for assuring that hardware enforcement is used.
■
For StorageWorks 1 Gb SAN switch fabrics, always use Domain/Port
identifiers only. Never identify a zone member by WWN.
■
For StorageWorks 2 Gb SAN switch and StorageWorks Core switch fabrics,
choose to use either WWN or Domain/Port zones. Never use both and never
used mixed zones.
■
For mixed fabrics always preferably use Domain/Port identifiers. If it is
desired to use WWN identifiers, the following methodology may be utilized.
Always place targets (disk and tape units) on the StorageWorks 2 Gb SAN
switches and StorageWorks Core switches, and use WWN zoning only. If all
the targets are on the StorageWorks 2 Gb SAN switches and StorageWorks
Core switches, then hardware enforced zoning will be active to protect them.
This does not hardware protect the initiators, but in general they do not offer
resources anyway and will reject any probe attempt by other initiators.
Summary of Contents for A7340A - Surestore FC 1Gb/2Gb Switch 16B
Page 12: ...About this Guide 12 Zoning Version 3 1 x 4 1 x User Guide ...
Page 18: ...Introducing Zoning 18 Zoning Version 3 1 x 4 1 x User Guide ...
Page 68: ...Zoning Concepts and Guidelines 68 Zoning Version 3 1 x 4 1 x User Guide ...
Page 70: ...Using Zoning to Administer Security 70 Zoning Version 3 1 x 4 1 x User Guide ...