Chapter 5
Troubleshooting
61
Is the power-and-cooling module DC Voltage/Fan
Fault/Service Required LED amber?
Is the drive enclosure back panel OK LED off?
Answer
Possible Reasons
Actions
No
System functioning properly.
No action required.
Yes
The power supply unit or a fan
is operating at an unacceptable
voltage/RPM level, or has
failed.
When isolating faults in the power-
and-cooling module, remember that
the fans in both modules receive
power through a common bus on the
midplane, so if a power supply unit
fails, the fans continue to operate
normally.
• Check that the power-and-cooling
supply FRU is firmly locked into
position.
• Check that the AC cord is
connected to a power source.
• Check that the AC cord is
connected to the power-and-
cooling module.
Answer
Possible Reasons
Actions
No
System functioning properly
No action required
Yes
• The expansion module is not
powered on.
• The controller module has
failed.
• Check that the drive is fully
inserted and latched in place,
• Check that the enclosure is
powered on.
• Check that the AC cord is
connected to a power source.
• Check the event log for specific
information regarding the failure.
Summary of Contents for AA988A - Modular Smart Array Storage Controller SCSI
Page 24: ...24 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Page 52: ...52 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Page 70: ...70 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Page 83: ...Appendix B Regulatory Compliance and Safety 83 Japanese Notice Korean Notices ...
Page 102: ...102 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...