74
HP StorageWorks 2012sa Modular Smart Array user guide • May 2008
Management Host Requirements
A local management host with at least one serial port connection is recommended
for the initial installation and configuration of a controller enclosure. After you
configure one or both of the controller modules with an Internet Protocol (IP)
address, you then use a remote management host on an Ethernet network to
configure, manage, and monitor.
Note –
Connections to this device must be made with shielded cables with metallic
RFI/EMI connector hoods in order to maintain compliance with FCC Rules and
Regulations.
Physical Requirements
The floor space at the installation site must be strong enough to support the
combined weight of the rack, controller enclosures, expansion enclosures, and any
additional equipment. The site also requires sufficient space for installation,
operation, and servicing the enclosures, and also requires sufficient ventilation to
allow a free flow of air to all enclosures.
Table A-1 and Table A-2 list enclosure dimensions and weights. Weights are based
on an enclosure having 12 drive modules, two controller or expansion modules, and
two power-and-cooling modules installed.
Table A-1
Rackmount Enclosure Dimensions
Specification
Rackmount
Height
2U 3.5 inches (8.9 cm)
Width:
• Chassis excluding mounting ears
• Chassis including mounting ears
17.6 inches (44.7 cm)
18.9 inches (48.0 cm)
Depth:
• Chassis
• To back of power-and-cooling module
handle
21.8 inches (55.4 cm)
23.7 inches (60.2 cm)
Summary of Contents for AA988A - Modular Smart Array Storage Controller SCSI
Page 24: ...24 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Page 52: ...52 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Page 70: ...70 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Page 83: ...Appendix B Regulatory Compliance and Safety 83 Japanese Notice Korean Notices ...
Page 102: ...102 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...