The HP AdvanceStack Switch 2000 user manual is a comprehensive resource providing a Quick Reference guide for smooth configuration and operation. Easily download this manual for free from our website to unlock the full potential of your device.
100Base-T Connectivity
17
Switch 2000 to Switch 2000
sd4pdf.fm5 Page 17 Thursday, February 20, 1997 4:31 PM
Page 1: ...VG LAN Adapters HP recommends setting the Mode to Master Other allowable Mode settings are shown in the illustrations on the following pages under Port Mode The port Mode can be set through the Configuration menu using the Switch 2000 console interface Connections 100VG ports on the Switch 2000 must not be connected to any 100VG ports labeled Uplink These ports are reserved for hub to hub connecti...
Page 2: ... Connectivity 2 Switch 2000 to 100VG Hub Switch 2000 to PC Use any Downlink port Port Mode Auto Detect OR End Node Any End Node For Example a PC or Server sd4pdf fm5 Page 2 Thursday February 20 1997 4 31 PM ...
Page 3: ...o Switch 2000 Switch 2000 to Switch 16 Auto Detect Auto Detect Master End Node Master End Node OR OR Port Modes Auto Detect Auto Detect Master End Node Master End Node OR OR Port Modes sd4pdf fm5 Page 3 Thursday February 20 1997 4 31 PM ...
Page 4: ...VG Connectivity 4 Switch 2000 to Switch 200 Switch 2000 to Router 650 0ORT ODE Auto Detect OR End Node Use Downlink Port Port Mode Auto Detect OR Master sd4pdf fm5 Page 4 Thursday February 20 1997 4 31 PM ...
Page 5: ...10Base T transceiver in the transceiver slot operates in MDI mode that is for con necting hubs or other switches to the Switch 2000 In this case use a straight through cable to connect the transceiver to an MDI X port on another device or a crossover cable to connect the transceiver to another trans ceiver or other MDI port on another device Note that if the connection from the 10Base T transceive...
Page 6: ... to Switch 2000 Switch 16 or Switch 200 Any End Node For Example a PC or Server Straight Through Cable Note This illustration also applies when connecting a Switch 2000 to a Switch 16 or a Switch 200 Crossover Cable sd4pdf fm5 Page 6 Thursday February 20 1997 4 31 PM ...
Page 7: ...Crossover Cable Illustrates use of Switch 800T s 10 100 capability for a 10 Mbit connection Port Mode Switch 2000 Half Duplex Switch 800T Auto Detect or 10 Half Dx Switch 2000 Full Duplex Switch 800T Auto Detect or 10 Full Dx Crossover Cable sd4pdf fm5 Page 7 Thursday February 20 1997 4 31 PM ...
Page 8: ...ration a straight through cable is used to connect the Router 650 to a built in RJ 45 port in the Switch 2000 Ether net module If the connection from the Router 650 is to a 10Base T transceiver in the Switch 2000 Ethernet module use a crossover cable instead Straight Through Cable sd4pdf fm5 Page 8 Saturday February 22 1997 12 00 PM ...
Page 9: ...for the Switch 2000 has four ports offering half duplex or full duplex operation The module supports the following fiber cable and connector types 62 5 125 µm multimode graded index fiber cable ST connectors Switch 2000 to an AdvanceStack Hub sd4pdf fm5 Page 9 Thursday February 20 1997 4 31 PM ...
Page 10: ...Fiber Optic 10Base FL Connectivity 10 Switch 2000 to Another Switch 2000 Switch 2000 to a Switch 16 OR sd4pdf fm5 Page 10 Thursday February 20 1997 4 31 PM ...
Page 11: ...Fiber Optic 10Base FL Connectivity 11 Switch 2000 to a Router 650 sd4pdf fm5 Page 11 Thursday February 20 1997 4 31 PM ...
Page 12: ...r example network speed and the transfer mode full or half duplex should be the same for both ports If Auto Negotiation is used between the ports both ports must comply with the IEEE 802 3u Auto Negotiation standard Configuration differences or use of devices that are not standards compliant could result in significant network errors For more information refer to the online Help included in the Sw...
Page 13: ...100Base T Connectivity 13 Switch 2000 to Switch 16 Switch 2000 to Switch 208T or 204 Crossover Cable Crossover Cable sd4pdf fm5 Page 13 Saturday February 22 1997 12 02 PM ...
Page 14: ...100Base T Connectivity 14 Switch 2000 to Switch 800T Switch 2000 to a Server or a PC Workstation Crossover Cable Straight Through Cables sd4pdf fm5 Page 14 Thursday February 20 1997 4 31 PM ...
Page 15: ...ivity 15 Switch 2000 to Another Switch 2000 Switch 2000 to an AdvanceStack 100Base T Hub Crossover Cable Crossover Cable Straight Through Cable MDI Port MDI X Port OR sd4pdf fm5 Page 15 Thursday February 20 1997 4 31 PM ...
Page 16: ...100Base T Connectivity 16 Fiber Optic 100Base T Connectivity Switch 2000 to Switch 800T Switch 2000 to Switch 208T sd4pdf fm5 Page 16 Thursday February 20 1997 4 31 PM ...
Page 17: ...100Base T Connectivity 17 Switch 2000 to Switch 2000 sd4pdf fm5 Page 17 Thursday February 20 1997 4 31 PM ...
Page 18: ... switch as a dual attach station DAS To attach the switch to two single attach stations To set up the switch as a dual homed device You can also use an optical bypass switch to prevent the FDDI ring from wrapping if the switch connected as a DAS loses power or if the FDDI port becomes available For more information on this topic refer to the installation guide provided for the FDDI Module Example ...
Page 19: ...ther MIC A or MIC B to any M Port on a Concentrator M M M M B A Primary FDDI Concentrator Secondary FDDI Concentrator Connect MIC A and MIC B to any M Port on Separate Concentrators M M M M B A M M M A M B Note The connection to the secondary concentrator operates only if the connection to the primary concentrator becomes disabled ROM ROM sd4pdf fm5 Page 19 Thursday February 20 1997 4 31 PM ...
Page 20: ...FDDI Connectivity 20 Example of FDDI Standalone Networking with Two SAS Connections PC Server Unix NFS Server sd4pdf fm5 Page 20 Thursday February 20 1997 4 31 PM ...
Page 21: ... 1997 Hewlett Packard Company Printed in Singapore 3 97 Part Number 5966 5215 5966 5215 sd4pdf fm5 Page 24 Thursday February 20 1997 4 31 PM ...