Replacing Bottom Drive – Front Access Storage Cage
1.
Shut down the system and remove the top cover as explained in Section 4.2.
2.
Remove the front access storage cage and all cables as explained in Section 4.6.
3.
Remove the four screws
n
from the sides of the bottom drive
o
and slide the drive
from the cage.
4.
Slide the new drive into the cage and insert the four screws.
5.
Reinstall the front access storage cage as explained in Section 4.6.
6.
Replace the top cover and reassemble the system enclosure as explained in the end of
Section 4.2.
7.
Turn on system power by pressing the power switch on the operator control panel. Boot
the operating system.
Verification
Enter the SRM and use the
init
and
show device
commands to verify that the system has
identified the new drive.
Installing and Configuring Options
4-15