Dialing In
This example shows the screen output when a modem connection is established.
ATDT915085553333
CONNECT 9600/ARQ/V34/LAPM
RMC Password: *****
Welcome to RMC V1.1-0
>>>
>>>
hp AlphaServer TS15 Remote Management Controller - Revision V1.1-0
RMC> status
hp AlphaServer TS15 Platform Status
RMC Runtime Firmware Revision: V1.1-0
RMC Booter Firmware Revision: V1.1-0
System Power: ON
System Halt: Deasserted
Escape Sequence: ^[^[RMC
Remote Access: Enabled
Modem RMC Defaults: Disabled Status: Initialized
RMC Password: Set
Alerts: Disabled Warning Alerts: Disabled
Alert Pending: NO
Latest Alert: AC Loss
Init String: AT&H2E0&C1&D0S0=2
Dial String: ATD915085554444
Alert String: ,,,,,,,,,,5551234
User String:
Com1 Baud:9600 Flow:SOFTWARE Mode:THROUGH Modem:DISABLED Rmc:ENABLED
Logout Timer: 20 minutes
Voltage Status: OK
Thermal Status: OK Thermal Shutdown: Enabled
Warning Threshold: 60.00°C Fatal/Power-Down Threshold: 65.00°C
Fan Status: OK Fan Shutdown: Enabled
PCI Riser: Installed
POST DPR: OK NVRAM: OK GPIOs: OK LM75: OK
Watchdog Timer: Disabled Watchdog Reboot: Disabled
RMC> hangup
+++
NO CARRIER
In the preceding example, enter commands at the RMC prompt to monitor and control the
remote system.
When you have finished a modem session, enter the
hangup
command to cleanly terminate
the session and disconnect from the server.
Unsetting the password
If the password is forgotten, you can reset it by using the
set password
command.
4.
Enter the
set password
command at the RMC prompt.
6-24
hp AlphaServer TS15 Owner’s Guide