6.8
Configuring Dial-Out Alert
When you are not monitoring the system from a modem connection, you can use the
RMC dial-out alert feature to remain informed of system status. If dial-out alert is
enabled, and the RMC detects alarm conditions within the managed system, it can call
a preset pager number.
You must configure remote dial-in for the dial-out feature to be enabled. See Section 6.7.
To set up the dial-out alert feature, enter the RMC from the COM1 serial terminal or local
VGA monitor.
Example 6–3 Dial-Out Alert Configuration
RMC> set dial
n
Dial String: atd915085554444
RMC> set alert
o
Alert String: ,,,,,,,,,,5551234
RMC> enable remote
p
Modem will be initialized when it is detected
RMC> clear alert
q
RMC> enable alert
r
RMC> send alert
s
RMC> status
t
hp AlphaServer TS15 Platform Status
RMC Runtime Firmware Revision: V1.1-0
RMC Booter Firmware Revision: V1.1-0
System Power: ON
System Halt: Deasserted
Escape Sequence: ^[^[RMC
Remote Access: Enabled
Modem RMC Defaults: Disabled Status: Not Initialized
RMC Password: Set
Alerts: Enabled Warning Alerts: Disabled
Alert Pending: YES
Latest Alert: Test alert generated by user request
Init String: AT&H2E0&C1&D0S0=2
Dial String: ATD915085554444
Alert String: ,,,,,,,,,,5551234
6-26
hp AlphaServer TS15 Owner’s Guide