6.10
Resetting the RMC to Factory Defaults
If the non-default RMC escape sequence has been lost or forgotten, RMC must be reset
to factory settings to restore the default escape sequence.
WARNING: To prevent injury, access is limited to persons who have
appropriate technical training and experience. Such persons are expected to
understand the hazards of working within this equipment and take measures
to minimize danger to themselves or others.
The following procedure restores the default settings:
1.
Shut down the operating system and unplug the power cord from the power supply.
2.
Remove the system cover (see Chapter 4) and wait for all the internal LEDs to go out.
3.
Insert the FORCE_DEFAULT jumper (J22 / pins 9 – 10) on the main logic board.
4.
Re-install the system cover and plug system in. Note: you do not need to power the
system on.
5.
When the RMC becomes available on the external COM1 port, the defaults have been
reset.
6.
Unplug the power cord.
7.
Remove the system cover and make sure all the internal system LEDs are not lit.
8.
Remove the FORCE_DEFAULT jumper from the main logic board.
9.
Re-install the system cover and plug in the system.
10.
Press the power button on the OCP to turn the system On.
Using the Remote Management Console
6-33