clear log
The
clear log
command clears all events from the system event log.
clear port
The
clear port
command clears the UARTs controlled by the RMC in an attempt to clear
any ‘stuck’ conditions that might exist.
disable alert
The
disable alert
command disables the RMC from paging the system operator in the event
that an alert condition is detected. System monitoring continues and any alert conditions
that are detected will still be logged.
disable fan
The
disable fan
command disables the system from powering off in the event that a fatal fan
failure occurs. By default, fan failures result in the system being powered off after a 3
minute lapse.
disable modemdef
This command instructs the RMC to use the user-supplied modem initialization string
without the additional commands that were automatically appended to the initialization
string on older
AlphaServer
and
AlphaStation
models.
disable reboot
The
disable reboot
command disables the watchdog timer from rebooting the system when
the watchdog timer expires. By default, the system does not reboot if the watchdog timer
expires.
disable remote
The
disable remote
command disables remote access to the RMC’s modem port and
disables automatic dial-out.
disable thermal
The
disable thermal
command disables the system from powering off in the event that a
thermal failure occurs. By default, thermal failures powers off the system after a 3-minute
lapse.
Using the Remote Management Console
6-37