Table 6–4 Initialization Commands with MODEMDEF Enabled
Modem
Command
Description
&C1
Normal Carrier Detect (CD) operations
&K
x
Select flow control per the current COM1 settings, where
x
is as
follows:
0: No flow control
3: Hardware flow control
4: Software (XON/XOFF) flow control
6: Both hardware and software flow control
enable reboot
The
enable reboot
command enables the watchdog timer to reset the system if the timer
should expire. By default, the system does not reset if the watchdog timer expires (and the
watchdog timer is enabled).
enable remote
The
enable remote
command enables remote access to the RMC’s modem port. It also
allows the RMC to automatically dial the pager number set with the
set dial
command upon
the detection of an alert condition, if alerts are enabled. Before the
enable remote
command can be used, the system must be configured for remote dial-in. See section 6.7.
enable thermal
The
enable thermal
command allows the RMC to power off the system in the event of an
over-temperature condition. By default, thermal failures powers off the system after a 3
minute lapse.
enable warning
The
enable warning
command allows warning-level events to generate system alerts (by
default, warnings do not generate alerts).
Note that alerts are delivered in the order in which they occur. Therefore, a pending
warning-level alert blocks the delivery of a fatal-level alert (although the fatal alerts
continue to be logged).
Using the Remote Management Console