Specification
Value
Rated input current
24 A at -40 VDC input
19 A at -48 VDC input, nominal input
12.4 A at -72 VDC input
Rated input power (W)
874 W at -40 VDC input
865 W at -48 VDC input, nominal input
854 W at -72 VDC input
Rated input power (BTUs per hour)
2,983 at -40 VDC input
2,951 at -48 VDC input, nominal input
2,912 at -72 VDC input
Power supply output
Rated steady-state power (W)
800 W at -40 VDC to -72 VDC
Maximum peak power (W)
800 W at -40 VDC to -72 VDC
Maximum peak power
800 W at 200 VAC to 277 VAC input
800 W at 380 VDC input
WARNING:
To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel, as defined by the NEC and IEC
60950-1, Second Edition, the standard for Safety of Information Technology Equipment.
• Connect the equipment to a reliably grounded secondary circuit source. A secondary circuit has
no direct connection to a primary circuit and derives its power from a transformer, converter, or
equivalent isolation device.
• The branch circuit overcurrent protection must be rated 27 A.
70