7062
Unable to back up all the files for the System Image tape.
Cause.
One of the files to be recorded on the system image tape (SIT) for SYSGEN was terminated.
Effect.
BACKUP terminates.
Recovery.
Correct the problem that caused the file to terminate and rerun SYSGEN.
7063
This System Image tape is for a different volume type
(DP1/DP2) System Disk. The OSIMAGE will not boot from the
current volume.
Cause.
The operating system contained in the OSIMAGE file could not be booted from the current
volume.
Effect.
RESTORE execution continues.
Recovery.
The system image tape (SIT) is built for a specific disk-process type, and the OSIMAGE
tape can only be booted on the correct disk process. Move the files to the correct disk process,
and retry the boot.
7064
Volume aborted. Cannot convert files when REBUILD is
specified.
Cause.
An attempt was made to convert files using the REBUILD option.
Effect.
No more files from the volume are processed, and RESTORE proceeds to the next volume.
Recovery.
Reenter the command without specifying REBUILD.
7066
Tape checksum error encountered in the data block.
Cause.
Checksum error encountered reading the tape.
Effect.
Warning message only.
Recovery.
Informational message only; no corrective action is needed.
7069
Volume aborted. Temporary conversion volume does not exist.
Use SCRATCHVOL parameter to specify a volume or make sure the
default volume exists.
Cause.
When attempting to convert files, either the current default volume or the indicated scratch
volume was nonexistent.
Effect.
BACKUP or RESTORE terminates.
Recovery.
Use the SCRATCHVOL parameter to specify a volume or (if the default volume is
nonexistent) select an existing volume using the command interpreter VOLUME command.