System Specifications and Requirements
Figure A-1
Power Supply Label
Table A-1
System Specifications
Description
Specification
Dimensions (H, W, D)
10.5 x 17 x 14 in (26.25 x 42.50 x 35.00 cm)
Weight (configured)
approximately 51 lbs (23.4 Kg)
Input Power
Operational:
-40 to -70 VDC (Margin included)
Recommended:
-48 to -60 VDC
Temperature
Operational:
+5 to +35C. (Goal: derate 4C/1000m above 1500m altitude)
(Commit: derate 2C/1000m above sea level)
Recom20 to +25C
Non-Operational:
-40 to +70C
Humidity
Operational:
15% to 80% RH non-condensing @35C
Recommended:
40% to 60% RH non-condensing
Maximum Altitude
Operational:
3000 meters above sea level
Non-Operational:
4500 meters above sea level
Acoustics
Sound Power:
54.0 dBA Bels LwA (not to exceed 7.5 Bels)
Table A-2
Power Consumption (Maximum)
Power Required
VA
a
Chassis
0.0 Watts
HP Server bp2200
89.0 Watts
FC Storage Blade
53.1 Watts
Management Blade
18.6 Watts
Management LAN Blade
7.0 Watts
System & Power Supply
Input Power
-48/ -60 VDC
20/ 16 A
System & Power Supply
Input Power
-48/ -60 VDC
20/ 16 A