(measured in Hertz), part number, serial number, and hardware
revision for the specified power supply if one is specified or for
all power supplies if ALL is given.
number, and hardware
revision.
SHOW ENCLOSURE
STATUS
Under an enclosure status heading, this command displays the
health of the enclosure, Integrated Administrator health, and
unit identification LED.
Under a power status heading, this command displays the
power status and capacity.
The command line adds the
Integrated Administrator
health.
UPDATE IMAGE <URL>
Downloads a new image from a server over the network and
uses the image to update the firmware of the enclosure.
All
UPLOAD CONFIG <url>
Uploads the current runtime configuration to the specified FTP
or TFTP server.
All
CLEAR SESSION BAY
<bay number>
Terminates a Terminal session from the enclosure.
All
CLEAR BAY BOOT [FIRST |
ONCE] [ALL | <bay number>
{[ , | - ] <bay number>}]
Clears the setting for the IPL to be passed to the blade at the
next reboot. The “FIRST” argument resets the IPL for all
subsequent reboots. The “ONCE” argument resets the IPL for
the next reboot only. This command is only valid for present
blades.
This command may require a firmware upgrade for the BIOS
ROM of certain HP blade PCs.
Only enclosure and group
administrators may execute
this command.
GENERATE NMI <bay
number>
POWERON BAY <bay
number> {[ , | - ] <bay
number>} {[PXE | HDD |
RBSU]}
Powers on the specified blade PC.
If no blade PC is in the specified bay, the user is told that the
bay is empty.
The optional boot arguments may require a firmware upgrade
for the BIOS ROM of certain HP blade PCs.
Adding an optional boot argument forces the blade to abandon
the regular boot order and forces a boot using the specified
method.
Allows for optional boot
argument
REBOOT BAY <bay
number> {[ , | - ] <bay
number>} {FORCE} {[PXE |
HDD | RBSU]}
Sends a request to the blade PC to perform a graceful
shutdown.
The blade PC is then powered on. If no blade PC is in the
specified bay, the user is told that the bay is empty.
The optional boot arguments may require a firmware upgrade
for the BIOS ROM of certain HP blade PCs.
Adding an optional boot argument with force the blade to
abandon the regular boot order and force a boot using the
specified method.
Allows for optional boot
argument
SET BAY BOOT FIRST
[HDD | PXE] <bay number>
{[ , | - ] <bay number>}
Sets the IPL for each subsequent reboot. This setting is only
valid for present blades and is cleared if a blade is removed.
This command may require a firmware upgrade of the BIOS.
Only enclosure administrators
may execute this command
SET BAY BOOT ONCE
[HDD | PXE | RBSU] <bay
number> {[ , | - ] <bay
number>}
Sets the boot device to be used on the next boot of the bay(s)
specified. This setting is only valid on present blades and is
cleared if the blade is removed.
Only enclosure administrators
may execute this command.
Table 5-9
Functions Exclusive to the Command Line Interface — Enclosure Management Commands
(continued)
ENWW
Functionality Exclusive to the Command Line Interface
65