Insight Display errors
The enclosure installation is successful when all errors are corrected. The errors in the following sections are
specific to installation and initial configuration of the enclosure. To clear errors that occur after initial
powerup and configuration, see the
HP BladeSystem Onboard Administrator User Guide
for information.
The following types of errors can occur when installing and configuring the enclosure:
•
Power errors (on page
80
)
•
Cooling errors (on page
81
)
•
Location errors (on page
81
)
•
Configuration errors (on page
81
)
•
Device failure errors (on page
81
)
When the enclosure UID LED is off, the Insight Display is illuminated amber when any error condition exists.
The navigation bar displays the following selections when an error condition exists:
•
Health summary icon—Displays the Health Summary screen.
•
Fix THIS—Suggests corrective action to clear the current error.
•
Next Alert—Displays the next alert, or if none exist, displays the Health Summary screen.
•
Previous Alert—Displays the previous alert.
Power errors
Power errors can occur because of insufficient power to bring up an enclosure. Power errors can occur on
blades, storage blades, or interconnect modules.
To correct a power error:
1.
Use the arrow buttons to navigate to
Fix This,
and press
OK.
2.
Review and complete the corrective action suggested by the Insight Display. In most cases, you must
either add power supplies to the enclosure or remove the indicated components.