HP Enclosure Options
HP BLc7000 Onboard Administrator with KVM Option
NOTE:
The HP c7000 OA supports the mixing with the HP c7000 OA with KVM. The HP
c7000 OA with KVM must be the active OA to provide the enclosure KVM feature. The
KVM menu has an OA CLI button at the bottom, which allows an OA administrator to log
into the OA and be able to force a takeover so the OA with KVM will become the standby
OA. The OA Firmware Sync feature cannot be used to update mismatched OA modules.
Mismatched OA firmware versions between the original c7000 OA and c7000 OA with
KVM require the administrator to use the GUI or CLI to update the OA from a file (http,
ftp, tftp, local client file using the GUI or USB key containing the OA firmware file).
NOTE:
Models of the c7000 enclosure (PN 681840-B21, 681842-B21, and 681844-B21)
come with a BladeSystem Onboard Administrator with KVM as standard. Order (P/N
456204-B21) when a second redundant BladeSystem Onboard Administrator is desired
for a c7000 enclosure.
NOTE:
HP ProLiant Gen8 server blades and certain options require the latest version of
the Onboard Administrator firmware. This firmware release may also require other
subsystem firmware upgrades. For information on the latest firmware versions, please
see the Blades Firmware Maintenance website at:
http://h18004.www1.hp.com/products/blades/components/c-class-compmatrix.html
.
456204-B21
HP BLc7000 10000 Series Rack Shipping Bracket Option
NOTE:
The shipping bracket is required when shipping a c7000 enclosure when installed
in a rack. It is not required for normal operation.
433718-B21
HP BLc7000 Miscellaneous Blanks Option Kit
NOTE:
Contains 1 each of c3000/c7000 Active Cool Fan blank, c3000/c7000
interconnect module blank, c7000 Onboard Administrator blank, c3000 local KVM
blank, c3000 power supply blank, c7000 power supply blank, c3000 DVD blank, and a
c3000 mini-divider.
NOTE:
This kit should only be ordered to replace lost or damaged blanks.
412148-B21
HP BLc7000 Server Blank w/Coupler Option
NOTE:
This is option contains one half-height device blank and a coupler that can be
used for the c3000 and c7000 enclosures.
NOTE:
Order quantity of one 412150-B21 for filling a half-height bay; the coupler is not
used.
NOTE:
Order quantity of two 412150-B21 for filling a full-height bay. One coupler is
installed between the two half-height blanks to be connected together to create a full-
height blank.
NOTE:
This kit should only be ordered to replace lost or damaged blanks.
412150-B21
HP Power Supplies
NOTE:
Mixing of Power Supplies Is Not Supported on BladeSystem c7000 Enclosures,
except during hot swaps to different level power supplies. OA will exhibit a mismatch
error due to mixed power supplies until all power supplies are matched.
NOTE:
If Three Phase Power Module selected, a minimum of 3 Power Supply Option Kits
are needed. For full redundancy 6 Power Supply Option Kits are required.
NOTE:
The 80 PLUS program is a unique forum that unites electric utilities, the
computer industry, and consumers in an effort to bring energy efficient technology
solutions to the marketplace. 80 Plus independently tests power supply efficiency and
publically posts the results on 80Plus.org."
QuickSpecs
HP BladeSystem c7000 Enclosure
Related Options
DA - 12810 Worldwide — Version 52 — December 10, 2013
Page 21