7.
Connect to the switch console, enter:
connect interconnect
<
bay number
>
8.
Change the password when prompted by the switch.
9.
To restore the con
fi
guration, you must disable the switch with the CLI, the integrated Web Tools GUI,
or the optional Fabric Manager GUI.
NOTE:
If using the CLI, enter
switchDisable
at the prompt. Refer to the
Fabric OS command reference
guide
for additional command information.
10.
Continue with the switch con
fi
guration. Enter the appropriate information when prompted. Make
sure that the data entered matches the settings on the faulty switch.
11.
Install the same Fabric OS version as the faulty switch using the CLI command
firmwareDownload
,
the integrated Web Tools GUI, or the optional Fabric Manager GUI.
12.
Verify that the appropriate licenses are installed on the replacement switch.
13.
Save the switch con
fi
guration
fi
le after making your edits; enter:
configupload
14.
Restore the switch con
fi
guration from the remote server using the backup con
fi
guration
fi
le from step 1.
15.
Enable the switch. Use the CLI command
switchenable
, the integrated Web Tools GUI or the
optional Fabric Manager GUI.
16.
Connect all external FC cables in the same port locations as before. To connect to the external
switch ports without connectivity to external devices, the external switch port must be disabled prior
to inserting the cable and then re
‐
enabled after inserting the cable to establish connectivity.
17.
Verify that the switch is joined to the fabric and all connected devices log in to the switch; enter:
switchshow
18.
Save the con
fi
guration
fi
le.
IMPORTANT:
HP recommends upgrading all switches in the enclosure to the latest available
fi
rmware. Check
http://www.hp.com
for updates.
Brocade 8Gb SAN Switch for HP BladeSystem c-Class
39
Summary of Contents for Brocade 8Gb SAN
Page 5: ...Index 61 Brocade 8Gb SAN Switch for HP BladeSystem c Class 5 ...
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Overview ...
Page 40: ...40 Managing the 8Gb SAN Switch ...
Page 46: ...46 Regulatory compliance and safety ...
Page 48: ...48 Electrostatic discharge ...
Page 52: ...52 SAN Switch technical specifications ...
Page 60: ...60 Glossary ...