Speci
fi
cation
Description
EMC immunity
•
IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge
•
IEC 61000-4-3 Severity Level 3 for Radiated Fields
•
IEC 61000-4-4 Severity Level 3 for Fast Transients
•
IEC 61000-4-5 Severity Level 3 for Surge Voltage
•
IEC 61000-4-6 Conducted Emissions
•
IEC 61000-4-11 Voltage Variations
•
EN 61000-4-12 Oscillatory Waves Immunity
•
EN 61000-3-2 Limits for Harmonic Current Emissions
•
EN 61000-3-3 JEIDA
System architecture
Nonblocking shared-memory switch
ANSI protocol
FC-PH (FC Physical and Signalling Interface standard)
Modes of operation
FC Class 2, Class 3, and Class F
Maximum frame size
2112-byte
Port-to-port latency
Less than 2 microseconds with no contention (destination
port is free)
Weight and physical dimensions
nl
Table 19
lists physical properties.
Table 19 8Gb SAN Switch physical dimensions
Dimension
Measurement
Height
29.3 mm (1.15 in)
Width
208 mm (8.19 in)
Depth
280 mm (11.02 in)
Weight
1.27 kg (2.8 lb)
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those
for which it was tested. The ranges speci
fi
ed in
Table 20
list the acceptable environment for both
operating and nonoperating conditions.
Table 20 Environmental requirements
Condition
Acceptable range during operation
Acceptable range during
non-operation
Ambient
temperature
104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level
-40°C to 70°C with maximum rate of
change of 20 C /hr
Humidity
5% to 90% relative humidity,
non-condensing
50% to 80% relative humidity,
non-condensing
Altitude
0 to 10,000 ft (3 km) above sea level
0 to 40,000 ft (12 km) above sea level
Shock
40 G, 2mS duration
140 G, 2mS,
Vibration
0.5 G, 10–500 Hz
2.0 G, 5–500 Hz
Air
fl
ow
47 cubic ft/minute
None required
50
SAN Switch technical speci
fi
cations
Summary of Contents for Brocade 8Gb SAN
Page 5: ...Index 61 Brocade 8Gb SAN Switch for HP BladeSystem c Class 5 ...
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Overview ...
Page 40: ...40 Managing the 8Gb SAN Switch ...
Page 46: ...46 Regulatory compliance and safety ...
Page 48: ...48 Electrostatic discharge ...
Page 52: ...52 SAN Switch technical specifications ...
Page 60: ...60 Glossary ...