210 Troubleshooting
ENWW
Stapler area
safety protection
activated
None
None
None
The number of sheets
in the print job
exceeds the number
of sheets that can be
stapled.
Recommended action:
1 Make sure that the number of sheets to staple is no more than 50 sheets of letter/A4 or 25 sheets of ledger/
A3 of 75-g/m
2
(20-lb) media.
2 See “Supported media” on page 44 if you are using heavy media. Media that is heavier than a 30-sheet job
of 199 g/m
2
(53 lb) might activate the safety sensor to protect the stapler unit.
3 Verify that the connectors at the controller PCA are correctly seated, and check the harness connection at
each end.
4 If the harness is connected, but the message persists, then replace the controller PCA.
Stapler low of
staples
None
None
None
Red blinking Green blinking
The staple cartridge
contains only 20 to 50
staples.
Recommended action:
Replace the staple cartridge.
Stapler out of
staples
None
None
None
Red blinking Yellow blinking
The staple cartridge is
out of staples.
Recommended action:
1 Replace the staple cartridge.
NOTE:
Customers might still see staples in the path of the cartridge. However, the “out of staples” message is
triggered when the staples chamber is empty. Print jobs will not be stapled.
2 Verify that the connectors at the controller PCA are correctly seated, and check the harness connection at
each end.
3 If the harness is connected, but the message persists, then replace the controller PCA.
4 If, after you replace the controller PCA, the message persists, then replace the stapler unit.
Too many pages
in job to staple
None
None
None
Red blinking
The number of sheets
in the document
exceeds the
maximum number of
sheets that the device
can staple.
Recommended action:
1 Make sure that the job to be stapled is within specifications. See chapter 3.
2 Reduce the number of pages to staple, and then perform a test.
3 Remove the back cover and verify the functionality of the stapler full-stack sensor PI25 (see page 82) by
using the sensor test (see “Testing sensors and switches” on page 238).
4 Verify that the connectors at the controller PCA are correctly seated, and check the harness connection at
each end.
5 If the harness is connected, but the message persists, then replace the controller PCA.
Too many pages
to make booklet
None
None
None
Red blinking
The number of sheets
in the document
exceeds the
maximum number of
sheets that the device
can fold.
Recommended action:
1 Make sure that the job to be saddle-stitched is within specifications. See chapter 3.
2 Reduce the number of pages to saddle-stitch and fold, and then perform a test.
3 If the job is within specifications, but the message persists, then replace the folding mechanism.
Table 27. Control panel and event log messages—multifunction finisher (continued)
Control panel
message
Event log, if connected to
User LED
Service LED
Description
LJ9000
9000mfp
9500, 9500mfp, 9050,
9050/9040mfp
Summary of Contents for C8088B
Page 1: ...service ...
Page 2: ......
Page 10: ...8 Contents ENWW ...
Page 44: ...42 Installation ENWW ...
Page 153: ...ENWW Chapter 6 Removal and replacement 151 Figure 118 Stacker controller PCA 2 2 2 2 1 3 2 3 ...
Page 299: ......
Page 300: ... 2004 Copyright Hewlett Packard Development Company L P Q5693 Q5693 90002 90002 Q5693 90002 ...