background image

©

 C

o

p

yr

ig

h

t 2

00

6 H

ew

le

tt-

P

ac

ka

rd

 D

ev

elo

p

m

en

t C

o

m

p

an

y, 

L

.P

.

    

  

Ja

n

u

ar

y 2

00

6 v

3

M

fg

. P

/N

: A

98

62

-9

60

05

*A

98

62

-9

60

05

*

A

do

be

 a

nd

 A

cro

ba

t a

re

 tr

ad

em

ar

ks

 o

f A

do

be

 S

ys

te

m

s I

nc

or

po

ra

te

d. 

Lin

ux

 is

 a

 re

gis

te

re

tra

de

m

ar

k o

f L

in

us

 T

or

va

ld

s. 

U

N

IX

 is

 a

 re

gis

te

re

d t

ra

de

m

ar

k o

f T

he

 O

pe

n G

ro

up

. M

ic

ro

so

ft®

 a

nd

 

W

in

do

w

 a

re

 U

.S

. re

gis

te

re

d t

ra

de

m

ar

ks

 o

f M

ic

ro

so

ft C

or

po

ra

tio

n.

cc3310
Carrier Grade
Server Software
& Setup
Reference Guide

Start Here

If you are not familiar with ESD (Electrostatic Discharge) procedures to
be used during system configuration, complete ESD procedures are
described in your 

cc3310 Product Guide

.

Thank you for buying a Hewlett Packard cc3310 Carrier Grade Server.
The following information will help you set up your server.

Expanded installation instructions and complete product information are
available on the 

hp server cc3310 user information diagnostics and utilitie

s

resource 

CD, which has been provided with your cc3310 server. 

 

Before you Begin

You will need the following tools and equipment:

Supplied by Customer

Monitor

Keyboard

Mouse

Additional I/O Cards

Box Contents

Resource CD

Server

PS/2 ‘Y’ Cable

AC Power Cable

(DC Cable Optional)

Documentation

Attach wrist strap to chassis ground 

(any unpainted metal surface) 

on the server

Flat Blade

Screwdriver

Antistatic

Wrist Strap

A

B

)

   Add additional hardware/cards, if desired. 
  Refer to the 

cc3310 Product Guide

 for further

  information.

D

)   Connect the keyboard and mouse cables to

  the PS/2 ‘Y’ cable.

E)

Connect the video monitor cable.

C

)

    Connect the keyboard/mouse PS/2 ‘Y’ cable
  to the server.

G

) Connect AC or DC power.  Make sure that the 

power service connection is through a properly
grounded outlet.  Refer to the 

hp server cc3310

    user information diagnostics and utilities 
    resource 

CD for additional information.

H

) You are now ready to apply power and install 
   the Operating System (OS).

Setting up the Hardware

1

The following web sites provide additional information 
and documentation about this server along with the 
latest downloadable firmware.  Perform a keyword 
search on cc3310 at the following URLs: 

http://www.hp.com/

for product information

Memory Loading Requirements and unique SCSI 
Addressing are described in the cc3310 Product Guide.
The cc3310 Product Guide is provided on the 
resource CD.

http://docs.hp.com/

for additional documentation

http://www.software.hp.com/

for any available downloadable drivers, firmware or
BIOS updates
You can also search HP's Support web site for
information about the server or supported operating
systems.

http://www.itrc.com/

Needle-nose

Pliers

   Carefully unpack the server.  Save all packing
  materials in case the server needs to be 
    shipped at a later time.

Phillips

Screwdriver

Operating System

1

USB 1

2

Video

3

U-320 SCSI

4

RJ-45 NIC 2

5

RJ-45 NIC 1

6

PS/2 mouse/keyboard

Rear Panel Connectors

7

RJ-45 Serial 2

8

USB 2

9

DB15 Alarm

Serial Adapter Cable

HP Server cc3310 User Information

Diagnostics and Utilities Resource CD

The resource CD is a dual-boot CD.  CD contents for each boot option
are listed below:

1. Online Boot:

  Insert CD while the operating system (OS) is running.

After the CD loads, the following tabs are available:

Server:

  Brief description of the cc3310

Utilities:

  Floppy creation utilities for SSU and diagnostics

Management SW: 

 ISM/TAM loader software/documentation

Documentation:

  Related product information plus Acrobat® Reader

I/O Information:

  Add-on I/O documentation

Training:

  Product training

Help:

  Navigation help for the resource CD

2. Offline Boot: 

 Boot from CD after hardware reset.  After the CD boots,

a wizard is launched that allows access to the following utilities:

Service Partition Administration Utility 

System Setup Utility (SSU) 

FRU/SDR Loader Utility

Diagnostics

Resource CD Contents

Front View 

cc3310 Server

Optional

Power

Supply

Full Height

PCI Card Slots

Low Profile

PCI Card Slots

Rear View

cc3310 with DC

Power Supply

Rear View

cc3310 with AC

Power Supply

B

1

2

3

4 5 6

7

8

9

G

DC Power

Supply

Optional

Power

Supply

What's Needed

-

hp server cc3310 user information diagnostics and utilities
resource 

CD.

- Operating System (OS) Media for the OS to be installed.
-

OS Support Notes

 for the selected OS. 

OS Support Notes

 

    can be found at http://www.docs.hp.com (search for cc3310) 
    and on the 

hp server cc3310 user information diagnostics 

    and utilities resource 

CD

.

Note: Microsoft® Windows® 2000 Advanced Server (AS) and 
Windows 2003 AS will require a unique "user developed 
and customized " installation CD.

What to Do

Install the OS as instructed in the Support Notes for your OS.  
Specific actions will vary, depending on the selected OS.

Installing an Operating System

2

Drive Bay 2

Drive Bay 2 

SCSI Connector

Engagement Lever

Drive Bay 1 

SCSI Connector

Engagement Lever

Peripheral Bay

Front Panel

 Control Switches 

and Status LEDs

RJ45 COM2 

and Dual USB 

Connectors

Drive Bay 1

Front View 

cc3310 Server 

with Bezel

Removed

Power Switch

Reset

Switch

Important Product Information

 Hardware Information

1.  The system Sensor Data Records (SDR) must be 

reprogrammed every time a configuration change 
is made to the hardware (memory, hard drives, 
power supplies, field replaceable units, etc.).
Failure to reprogram the SDR could result in NO 
alarms when a critical system failure occurs or 
invalid alarms when NO failure occurs.

2.  When installing memory, you must adhere to the 

memory configuration requirements and to the 
proper loading sequence. Refer to the cc3310  
Product Guide for additional information.

3.  Systems are shipped with the service partition 

installed on the internal boot drive.  The service 
partition contains utilities, diagnostics, and other 
support software.

4.  Installing a service partition will remove any 

previously installed OS.

5.  The fault lights of the TAM display are factory- 

configured with North American settings.  Refer 
to the cc3310 Product Guide for instructions to 
reconfigure this display.

6.  Only the NIC 1 port (lower port at rear) can be 

used with the Intel Service Manager (ISM).

7.  One RJ-45 to DB9 serial connector is shipped 

with each server. Use this connector for the rear 
RJ-45 port. A different and unique interface (pin-out) 
is required for use with the front RJ-45 port.

 Linux Information

1.  If you will be using a USB floppy drive, install the 

drive before installing Linux.

2. Install all SCSI controllers before installing a 

Linux OS.

3.  Linux will change the boot order when a new 

SCSI controller is installed.

4.  Linux must always be installed on the first hard 

drive of the system (first drive, channel b, internal 
SCSI interface).

 Windows Information

1.  A "user developed and customized" CD is required 

before Windows 2000 AS and Windows 2003 AS can
be installed. Instructions on how to build this CD can 
be found at "Operating System (OS) Support Notes 
for Windows 2000 Advanced Server on hp cc3310" 
or "Operating System (OS) Support Notes for 
Windows 2003 Advanced Server on hp cc3310" at 
http://www.docs.hp.com (search for cc3310) and on 
the

 hp server cc3310 user information diagnostics 

and utilities resource 

CD

.

Need More Info?

Monitor

E

C
D

Keyboard

Mouse

F

)  If you are using a serial console, connect the

    serial adapter cable to the rear RJ-45 port and
    turn on console redirect. Refer to the 

cc3310

    

Product Guide

 for further information.

F

To
Serial
Console

Reviews: