Table 10 Fan In, Fan Out and job concurrency rules, B6000 products
maximum couplets (4)
Per node (couplet)
64
8 (16)
Maximum number of Target
appliances supported by
one Source appliance
Appliance Fan Out
384
48 (96)
Maximum number of Source
appliances supported by
one Target appliance
Appliance Fan In
8
1 (2)
Maximum number of Target
libraries to which a Source
library may be mapped
Library Fan Out
128
16 (32)
Maximum number of Source
libraries to which a Target
library may be mapped
Library Fan In
128
16 (32)
Maximum number of
concurrent replication jobs
into a target appliance
Concurrent target jobs
384
48 (96)
Maximum number of
concurrent replication jobs
from a source appliance
Concurrent source jobs
Table 11 Fan In, Fan Out and job concurrency rules, G2 products
HP D2D 4312/4324
HP D2D 4106/4112
HP D2D 2502/2504
8
4
2
Maximum number of
Target appliances
Appliance Fan Out
supported by one
Source appliance
50
D2D4106: 16
D2D4112: 24
D2D2502: 4
D2D2504: 8
Maximum number of
Source appliances
Appliance Fan In
supported by one
Target appliance
1
1
1
Maximum number of
Target libraries to
Library Fan Out
which a Source library
may be mapped
16
8
1
Maximum number of
Source libraries to
Library Fan In
which a Target library
may be mapped
16
8
4
Maximum number of
concurrent replication
Concurrent target jobs
jobs into a target
appliance
48
24
8
Maximum number of
concurrent replication
Concurrent source
jobs
jobs from a source
appliance
Table 12 Fan In, Fan Out and job concurrency rules, G1 products
HP D2D 4112
HP D2D 4004/4009
HP D2D 250x
4
4
All: 2
Maximum number of
Target appliances
Appliance Fan Out
supported by one
Source appliance
30