Base Address with
HP Command
Modules
To calculate the base address when using the HP E1413 with HP Command
Modules (HP E1405B/E1406) add 1F0000
16
or 2,031,616
10
to the VXIbus
Register Base Address.
Figure D-1. HP E1313/E1413 Registers within A16 Address Space
Module Base Address =
1FC000
16
+ logical address
16
* 40
16
or
2,080,768
10
+ logical address
10
* 64
10
Register Address = Base A Register Offset