Options A3E and A3H
Terminals
The P/J jumper connection for each channel is named CH X PRGM JMPR
in the connection diagram on page 30. With no connection to this pin, the
module will operate in the Program Selectable mode. Shorting this pin to
GND will set the Jumper Selectable mode for channel X.
When CH X PRGM JMPR is shorted to GND, the CH X MODE JMPR pin
(corresponding to the V/I Jumper) sets the output mode for channel X. If
the pin is open, voltage output mode is selected. If the pin is shorted to
GND, current output mode is selected for channel X.
32 Module Setup and Installation