:ENABle?
[:EVENt]?
STATus:OPERation:CONDition?
STATus:OPERation:CONDition?
returns the contents of the Operation Status
Condition Register. Reading the register does not affect its contents.
Parameters
Returns: 16-bit signed integer (int16).
Comments
•
Bit 0 of this register (decimal 1) is the Calibrating bit. This bit is set when:
–
the
CALibration:CONFigure:RESistance?
,
CALibration
n
:CONFigure:VOLTage?
,
or
CALibration
n
:CONFigure:CURRent?
command has been received and,
–
measurements with the corresponding
CALibration:VALue:RESistance
,
CALibration
n
:VALue:VOLTage?
, or
CALibration
n
:VALue:CURRent?
commands
are not complete.
•
*RST Condition: clears all conditions.
•
*CLS
and
STATus:PRESet
do not affect bits in the Status Operation Condition
Register.
STATus:OPERation:ENABle
STATus:OPERation:ENABle <
mask
>
specifies which bits of the Operational
Status Event Register are OR’d together to create the Operational Status bit (bit 7)
in the Summary Register of the Status Byte.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
<
mask
>
numeric (int16) or
non-decimal numeric
-32768 to +32767 or #H0000 to #HFFFF
none
Comments
•
Only bit 0 (decimal 0) is used or defined in the Operation Register. Bit 0 is
defined as the Calibrating bit. A 1 in this bit indicates the module is currently in
the calibration mode.
•
The non-decimal numeric forms are the #H, #Q, or #B formats specified by
IEEE-488.2.
•
*RST
clears all conditions.
•
*CLS
and
STATus:PRESet
do not affect bits in the Operation Status Condition
Register.
STATus
95 HP E1418A SCPI Command Reference
Chapter 3
Summary of Contents for E1418A
Page 6: ...Notes 6 Contents HP E1418A 8 16 Channel D A Converter Module ...
Page 10: ...Notes 10 HP E1418A User s Manual ...
Page 12: ...12 HP E1418A User s Manual ...
Page 105: ...TRIGger 105 HP E1418A SCPI Command Reference Chapter 3 ...
Page 111: ...Notes HP E1418A Command Quick Reference 111 HP E1418A SCPI Command Reference Chapter 3 ...
Page 135: ...135 HP E1418A Register Based Programming Appendix B ...
Page 157: ...Notes 156 HP E1418A Error Messages Appendix C ...
Page 170: ...Notes Appendix D Voltage Current Output Adjustment 169 ...
Page 174: ...Figure E 1 8 Channel Disassembly 172 Configuration and Disassembly Appendix E ...
Page 175: ...Figure E 2 16 Channel Disassembly Appendix E Configuration and Disassembly 173 ...
Page 192: ...Notes 192 HP E1418A 8 16 Channel D A Converter Module Index ...