8
HP E1586A Rack Mount Terminal Panel
The following shows how to connect the thermistors to the HP E1413C/
E1415A current source. For the Terminal Panel’s on-board thermistors
excitation, connect HI-I to HI-TI, and LO-I to LO-TI, respectively.
Connecting One Terminal Panel for Reference Temperature
Measurements
In this configuration, a single Terminal Panel is used with an HP E1413C/
E1415A to provide up to 32 channels for temperature measurements. Make
the following connections on the thermistor terminal block of the Terminal
Panel: Connect HI-I to HI-TI Connect LO-I to LO-TI
This provides the excitation current to all three on-board thermistors on the
Terminal Panel. Figure 3 on page 8 shows the connection for a single
Terminal Panel
Connecting Two Terminal Panels for Reference Temperature
Measurements
In this configuration, two Terminal Panels are used with an HP E1413C/
E1415A to provide up to 64 channels for temperature measurements. Make
the following connections on the thermistor terminal blocks of both
Terminal Panels:
Connect HI-I to HI-TI of the First Terminal panel Connect LO-I to LO-TI of
the First Terminal Panel Connect LO-TI of the First Terminal Panel to HI-
TI of the Second Terminal Panel Connect LO-TI of the Second Terminal
Panel to LO-I of the First Terminal Panel.
This provides the excitation current to all six on-board thermistors on the
Terminal Panels. Figure 4 on page 9 shows the connection for two Terminal
Panels.
Figure 3. Connecting Three Thermistors on a Single Panel
Connects All
Thermistors
One HP E1586 Terminal Panel
using All Thermistors
Summary of Contents for E1586A