131
Step Command
Remarks
8.
Set CIR ALLOW for FR
PVCs.
cir allow
[
inbound
]
committed-information-rate
Optional.
The default setting is 56000 bps.
Configuring FR congestion management
FR congestion management includes congestion management on the FR interface and congestion
management on the FR PVC. You can set the congestion thresholds in FR PVC view or FR interface
view for a specific FR class.
Configuring FR congestion management for an FR interface
The device determines whether congestion occurs based on the percentage of the current FR
interface queue length to the total interface queue length. If the percentage exceeds the set
congestion threshold, the device considers congestion has occurred and takes action on packets (for
example, drops packets), to alleviate the condition.
To configure FR congestion management for an FR interface:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter FR interface view.
interface
interface-type
interface-number
N/A
3.
Enable FR congestion
management on the FR
interface.
fr congestion-threshold
{
de
|
ecn
}
queue-percentage
By default, FR
congestion
management is
disabled for an FR
interface.
Configuring FR congestion management for an FR PVC
The device determines whether congestion has occurred based on the percentage of the current FR
PVC queue length to the total interface queue length. If the percentage exceeds the set congestion
threshold, the device considers that congestion has occurred and takes action on packets (for
example, drops packets), to alleviate the condition.
When you configure FR congestion management for an FR PVC, follow these guidelines:
•
With FR congestion management enabled, an FR interface performs only FIFO queuing or PVC
PQ.
•
With FR congestion management enabled, an FR PVC performs only FIFO queuing.
•
To use congestion management on an FR PVC, make sure that FRTS has been enabled on the
main interface of the FR PVC.
To configure FR congestion management for an FR PVC:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter FR class view.
fr class
class-name
N/A
3.
Enable FR congestion
management for FR PVCs.
congestion-threshold
{
de
|
ecn
}
queue-percentage
By default, FR congestion
management is disabled
for FR PVCs.