475
Link ID : 8 PW State : Up
In Label : 1279 Out Label: 1278
MTU : 1500
PW Attributes : Main
VCCV CC : -
VCCV BFD : -
Tunnel Group ID : 0x660000000
Tunnel NHLFE IDs : 1031
Peer: 3.3.3.9 PW ID: 500
Signaling Protocol : LDP
Link ID : 9 PW State : Up
In Label : 1277 Out Label: 1277
MTU : 1500
PW Attributes : Main
VCCV CC : -
VCCV BFD : -
Tunnel Group ID : 0x670000000
Tunnel NHLFE IDs : 1032
H-VPLS UPE dual homing configuration example
Network requirements
To improve reliability of the H-VPLS network, the UPE establishes a U-PW with NPE 1 and NPE 2.
The U-PW between UPE and NPE 1 is the primary PW and that between UPE and NPE 2 is the
backup PW. The backup PW works only when the primary PW fails.
The H-VPLS uses LDP as the PW signaling protocol.
Figure 128 Network diagram
Configuration procedure
1.
Configure an IGP and public tunnels on each PE. (Details not shown.)
Loop0
1.1.1.1