117
Appendix B LEDs
HPE HSR6800 routers provide LEDs for FRUs to indicate their operating status.
MPU and switching fabric module LEDs
The LEDs for the RSE-X2 and RSE-X3 are the same.
uses the RSE-X2 as an example.
Figure 85 RSE-X2 LEDs
Table 63 RSE-X2 LED description
LED Status
Description
(green)
CF
Off
No CF card is present or the CF card is not recognizable.
Steady on
A CF card is in position and has been detected.
Flashing
The system is accessing the CF card.
CAUTION:
In this state, do not insert or remove the CF card to avoid
damaging the file system on the CF card.
(green/orange)
LINK
Off
No link is present on the port.
Steady green
A 1000 Mbps link is present.
Steady orange
A 10/100 Mbps link is present.
(yellow)
ACT
Off
No data is being received or transmitted.
Flashing
Data is being received or transmitted at 10/100/1000 Mbps.
(red)
ALM
Off
The system is operating correctly and there is no alarm.
Steady on
A fault has occurred to the system. In this state, check the
system log immediately.
(red)
PAL
M
Off
The system power supply is operating correctly.
Steady on
The available power is not efficient, or power supplies of
different specifications are inserted.
(green)
ACT
Off
The MPU is in standby state.
Steady on
The MPU is in active state.