15
1.
Face the front of the router and locate the slot.
2.
Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot.
Keep the removed filler panel for future use.
3.
Insert the SFE-X1 slowly along the slide rails until positioning pins on the backplane are seated
in the positioning holes, and then push the ejector levers inward to lock the SFE-X1 in position.
4.
Use a Phillips screwdriver to fasten the captive screws on the two sides of the SFE-X1.
For the SFE-X1 LED description, see "
MPU and switching fabric module LEDs
Figure 13 Installing an SFE-X1
Installing LPUs
CAUTION:
The RUN LED flashes quickly when the FIP is starting up. To avoid hardware damage, do not install
or remove a HIM/MIM when the LED is flashing quickly.
Slot 3 of the HSR6802/HSR6804 and Slot 7 of the HSR6808 are not provided with filler panels.
Before installing an LPU, pivot the ejector levers on the LPU outward..
The procedures for installing LPUs are similar. This procedure uses a FIP-210.
To install a FIP-210: