59
PALM LED is steady on
Symptom
The PALM LED for the MPU is steady on. For more information about MPU LEDs, see
.
Solution
To resolve the problem:
1.
Verify that the power supply and power consumption match.
For example, if an HSR6808 is installed with a 650 W power supply but two SAP-48GBE
modules, the power available is not sufficient for the whole power consumption and one SAP
module cannot be powered on.
2.
Verify that the router has one type of power supplies installed: AC power supplies or DC power
supplies.
3.
If the problem persists, contact Hewlett Packard Enterprise Support.
Table 22 MPU LEDs
LED Status
Description
RUN (green)
Off
No power is provided or the MPU is faulty.
Flashing slowly at 1 Hz
The MPU is operating correctly.
Flashing fast at 8 Hz
•
The MPU is loading system software images. To avoid
MPU damage, do not power off the router or hot-swap
the MPU.
•
The MPU is not operating.
ACT (green)
Off
The MPU is in standby state.
Steady on
The MPU is in active state.
PALM (red)
Off
The power supply is operating correctly.
Steady on
The power for use is not sufficient, or power supplies of
different specifications are inserted.
ALM (red)
Off
The system is operating correctly without any alarm.
Steady on
The system is faulty. View the system logs.
Flashing fast at 8 Hz
The system is seriously faulty and immediate action is
needed.
LPU failures
RUN LED is off
Symptom
The RUN LED for the LPU is off.
Solution
To resolve the problem:
1.
Verify that the router is powered on.
2.
Verify that the LPU is correctly inserted in a slot.
3.
Verify that the system power is sufficient. If the system power is insufficient, the system displays
the following information: