116 Section 10: The Index Register and Loop Control
I
and
e
For the purpose of loop control, the integer portion (the counter value) of
the stored control number can be up to five digits long (
nnnnn.xxxyy
). The
counter value (
nnnnn
) is zero if not specified otherwise.
xxx,
in the decimal portion of the control number, must be specified as a
three-digit number. (For example, ―5‖ must be ―005‖.)
xxx
is zero if not
specified otherwise. Whenever
I
or
e
is encountered, nnnnn is
compared internally to
xxx,
which represents the end level for incrementing
or decrementing.
yy
must be specified as a two-digit number.
yy
cannot be zero
, so if
left (or
specified) as
00
,
the value for
yy
defaults to
1
.
The value
nnnnn
is altered
by the amount of
yy
each time the loop runs through
I
or
e
. Both
yy
and
xxx
are reference values, which do
not
change with loop execution.
Indirect Display Control
While you can use the Index register to format the display manually (that is,
from the keyboard), this function is most commonly used in programming.
This capability is especially valuable for the
f
function, for which
accuracy can be stipulated by specifying the number of digits to be
displayed (as described in section 14).
There are, as usual, certain display limitations to keep in mind. Recall that
any display format function merely alters the number of decimal places to
which the display is rounded. In its memory, the calculator always retains a
number in scientific notation as a 10-digit mantissa with a two-digit
exponent.
The integer portion of the number in the Index register specifies the number
of decimal places to which the display is rounded. A number less than zero
defaults to zero (zero decimal places displayed in
•
format), while a
number greater than 9 defaults to 9 (9 decimal places displayed in
•
).*
* Note that in
i
and
^
format modes, the maximum display is a seven-digit mantissa
with a two-digit exponent. However, a format number greater than six (and less than or equal
to nine)