HPONCFG Online Configuration Utility
263
Windows Server Installation
1. To install HPONCFG, run the self-extracting executable delivered in the
Softpaq from within a directory of your choice on the managed server.
Choose the directory from which the HPONCFG utility is executed. This
directory will also contain the XML formatted input scripts and store the
output files from execution of the utility.
2. Unzip all files in the delivered zip file HPONCFG.ZIP to the same directory.
Linux Server Installation
1. Copy the file hponcfg-1.00.tar.gz to a temporary directory on the managed
server.
2. Use the tar utility to extract all of the files. The package contains the
following files:
−
hponcfg-1.0.rh72-0.1.i386.rpm (RPM package for Red Hat 7.2)
−
hponcfg-1.0.rh73-0.1.i386.rpm (RPM package for Red Hat 7.3)
−
hponcfg-1.0.rh8-0.1.i386.rpm (RPM package for Red Hat 8.0)
−
hponcfg-1.0.sles7-0.1.i386.rpm (RPM package for SLES 7)
−
hponcfg-1.0.ul10-0.1.i386.rpm (RPM package for United Linux 1.0)
3. Install the appropriate package using the RPM installation utility. The
HPRSM RPM package must be installed before installing the HPONCFG
RPM package.
Example:
HPNOCFG RPM can be installed on Red Hat 8.0 by using the following
command:
rpm -ivh hponcfg-1.0.rh8-0.1.i386.rpm
4. Unzip all files in the delivered zip file, HPONCFG sample scripts.zip, to a
working directory.
5. After installation, run the HPONCFG executable found in the /sbin directory.
Summary of Contents for HP Integrated Lights-Out
Page 1: ...HP Integrated Lights Out User Guide July 2004 Sixth Edition Part Number 238882 006 ...
Page 20: ......
Page 134: ......
Page 142: ......
Page 192: ......
Page 222: ......
Page 232: ...232 User Guide Integrated Lights Out ...
Page 240: ......
Page 268: ......
Page 362: ......
Page 406: ......