Remote Insight Command Language
273
/>
•
•
•
RESPONSE
This tag name indicates that iLO is sending a response to the previous
commands back to the client application to indicate the success or failure of
the commands that have been sent to iLO.
STATUS
This parameter contains an error number. The number “0x0000” indicates
that there is no error.
MSG
This element contains a message describing the error that happened. If no
error occurred, the message “No error” is displayed.
RIBCL
This command is used to start and end an RIBCL session. You can use it only
once to start an RIBCL session, and it must be the first command to display in
the script. The RIBCL tags are required to mark the beginning and the end of the
RIBCL document.
Example:
<RIBCL VERSION="2.0">
</RIBCL>
RIBCL Parameter
VERSION is a string that indicates the version of the RIBCL that the client
application is expecting to use. The VERSION string is compared to the version
of the RIBCL that is expected, and an error is returned if the string and the
version do not match. The preferred value for the VERSION parameter is "2.0."
The VERSION parameter is no longer checked for an exact match; however, this
parameter can never be blank.
RIBCL Runtime Errors
The possible RIBCL error messages include: