Remote Insight Command Language
313
MOD_BLADE_RACK Runtime Errors
The possible MOD_BLADE_RACK error messages include:
•
•
•
•
•
Rack information is open for read-only access. Write access is required for
this operation.
Rack Name too long.
Enclosure Name too long.
Bay Name too long.
User does not have correct privilege for action. CONFIG_ILO_PRIV
required.
GET_DIAGPORT_SETTINGS
The GET_DIAGPORT_SETTINGS command requests the respective iLO
diagnostic port settings. For this command to parse correctly, the
GET_DIAGPORT_SETTINGS command must appear within a RACK_INFO
command block, and RACK_INFO MODE can be set to read or write.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RACK_INFO MODE="read">
<GET_DIAGPORT_SETTINGS/>
</RACK_INFO>
</LOGIN>
</RIBCL>
GET_DIAGPORT_SETTINGS Parameters
None
GET_DIAGPORT_SETTINGS Runtime Errors
None