Configuring
iLO
37
•
GET_ENCLOSURE_IP_SETTINGS—Requests the respective iLO Static IP
Bay Configuration settings. This attribute must appear inside the
RACK_INFO command block. The RACK_INFO command block may be
set to read or write.
RIBCL RACK_INFO Command Examples
Getting Static IP Bay Configuration Settings
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="Admin" PASSWORD="password">
<RACK_INFO MODE="write">
<GET_ENCLOSURE_IP_SETTINGS/>
</RACK_INFO>
</LOGIN>
</RIBCL>
Modifying Static IP Bay Configuration Settings
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="Admin" PASSWORD="password">
<RACK_INFO MODE="write">
<MOD_ENCLOSURE_IP_SETTINGS>
<BAY_ENABLE MASK="0x3FE"/>
<IP_ADDRESS VALUE="16.100.222.111"/>
<SUBNET_MASK VALUE="255.255.252.0"/>
<GATEWAY_IP_ADDRESS VALUE="16.100.222.1"/>
<DOMAIN_NAME VALUE="sum.won.here.now"/>
<PRIM_DNS_SERVER VALUE="16.11.1.111"/>
<SEC_DNS_SERVER VALUE=""/>
<TER_DNS_SERVER VALUE=""/>
<PRIM_WINS_SERVER VALUE="16.22.2.222"/>
<SEC_WINS_SERVER VALUE=""/>
<STATIC_ROUTE_1 DEST="16.33.3.33"
GATEWAY="16.100.11.11"/>
<STATIC_ROUTE_2 DEST="" GATEWAY=""/>
<STATIC_ROUTE_3 DEST="" GATEWAY=""/>
</MOD_ENCLOSURE_IP_SETTINGS>
</RACK_INFO>
</LOGIN>
</RIBCL>
Modify Network Settings to Enable Static IP Bay Configuration