Code
Issue
Possible solution
EA
Fan rotor failure - Fan Module 2
Replace the fan module.
EB
Communication write error - Fan
Module 1
• Reseat the fan module.
• Replace the fan module.
EC
Communication write error - Fan
Module 2
• Reseat the fan module.
• Replace the fan module.
F0
Permanent error in PS1/Fan 2
(Drawer 2) I2C bus
• Reseat Power Supply 1.
• Reseat Fan Module 2 (Drawer 2).
F1
Permanent error in PS2/Fan 1
(Drawer 2) I2C bus
• Reseat Power Supply 2
• Reseat Fan Module 1 (drawer 2).
F2
Permanent error in PS3/Fan 2
(Drawer 1) I2C bus
• Reseat Power Supply 3.
• Reseat Fan Module 2 (drawer 1).
F3
Permanent error in PS4/Fan 1
(Drawer 1) I2C bus
• Reseat Power Supply 4.
• Reseat Fan Module 1 (drawer 1).
F4
Enclosure identity conflict
Requires specific documentation for the procedure. See the
procedure about recovering from a power failure reported from
the backplane in the HPE D6020 Disk Enclosure Maintenance and
Service Guide.
F4
NVRAM backup failure on top I/O
module
Refer to drawer and power block assembly FRU replacement
documentation.
F5
NVRAM backup failure on bottom
I/O module
Refer to drawer and power block assembly FRU replacement
documentation.
F6
A drawer is currently open
Close the drawer.
Indications of disk drive failure
When troubleshooting drive problems, first confirm that the drives are supported for use in the D6020. For more
information, see the D6020 QuickSpecs:
https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=c05054941
In a D6020, a steadily glowing fault LED indicates that the drive has failed.
Other indications of failed disk drives:
• The HPE Smart Storage Administrator represents failed drives with a distinctive icon.
• HPE SIM can detect failed drives remotely across a network. (For more information about HPE SIM, see the
documentation.)