Viewing power information
Procedure
1.
Click
Power & Thermal
in the navigation tree, and then click the
Power
tab.
The information displayed on the
Power Information
page varies depending on the server type. The
following sections are possible:
•
Power Supply Summary
•
Power Supplies
•
HPE Power Discovery Services
•
Battery Backup Units
•
Smart Storage Battery
•
Power Readings
•
Power Microcontroller
If the server is powered off, the system health information on this page is current as of the last power
off. Health information is updated only when the server is powered on and POST is complete.
Power Supply Summary details
This section is displayed for nonblade servers.
Present Power Reading
When Common Slot Power Supplies are present, the most recent power reading from the server is
displayed. Other power supplies do not provide this data.
Although this value is typically equal to the sum of all active power supply outputs, there might be
some variance as a result of reading the individual power supplies. This value is a guideline value and
is not as accurate as the values presented on the
Power Meter
page. For more information, see
on page 149.
Power Management Controller Firmware Version
The firmware version of the power management controller. The server must be powered on for the
iLO firmware to determine this value. This feature is not available on all servers.
Power Status
The overall status of the power supplied to the server.
• If the server power supplies are connected to a nonintelligent power source, this section displays
the status of the internal server power supplies.
• If the server power supplies are connected to Power Discovery Services through an iPDU, this
section displays the status of the power supplied to the internal server power supplies.
Possible
Power Status
values follow:
•
Redundant
—Indicates that the power supplies are in a redundant state.
Viewing power information
157